NORDTEK DANMARK - EI30 - Encapsulated PCB Mount 50/60Hz Transformer - 0.6-4.8VA - servicekontoret.dk

Tell a friend Enquiry print

EI30 - Encapsulated PCB Mount 50/60Hz Transformer - 0.6-4.8VA

Our comprehensive selection of products also includes a series of EI30 safety transformers for PCB mounting.

High-quality encapsulated vacuum potted short-circuit proof transformers. Output power from 0.6VA.

  Print Layout - EI30 Transformer   Pin and Transformer height   EI30 - EncapsulatedPCB Mount 50/60Hz Transformer - 0.6-4.8VA  
 
View from PCB   Solder pins 0.8 mm Ø  - Grid 5 mm


Type * Stack
height
mm
Case
height
mm
Weight
g
 EI30-X10/7.../.. 70°C/B 6...24V - 0.70 VA 2x6...12V - 2x0.30 VA x x ukf 5.0 15.5 44
 EI30-X6/7.../... 70°C/B 6...28V - 1.50 VA 2x6...14V - 2x0.65 VA x x ukf 10.5 23.0 75
 EI30-X6/4.../... 40°C/B 6...26V - 1.70 VA 2x6...13V - 2x0.75 VA x   ukf 10.5 23.0 75
 EI30-Y7/7.../... 70°C/B 6...29V - 1.70 VA 2x6...14V - 2x0.75 VA x x ukf 12.5 24.7 85
 EI30-Y7/4.../... 40°C/B 6...27V - 2.00 VA 2x6...13V - 2x0.90 VA x   ukf 12.5 24.7 85
 EI30-Y8/7.../... 70°C/B 6...28V - 2.00 VA 2x6...14V - 2x0.90 VA x x ukf 15.0 27.3 98
 EI30-Y8/4.../... 40°C/B 6...27V - 2.40 VA 2x6...13V - 2x1.10 VA x   ukf 15.0 27.3 98
 EI30-Y8F/7.../... 70°C/B 6...32V - 2.40 VA 2x6...16V - 2x1.10 VA x x ukf 15.0 27.3 98
 EI30-Y9/7.../... 70°C/B 6...28V - 2.30 VA 2x6...14V - 2x1.00 VA x x ukf 18.0 30.2 117
 EI30-Y9F/7.../... 70°C/B 6...30V - 2.70 VA 2x3...15V - 2x1.25 VA x x ukf 18.0 30.2 117
 EI30-Y9/4.../... 40°C/B 6...28V - 2.80 VA 2x6...14V - 2x1.30 VA x   ukf 18.0 30.2 117
 EI30-Y10/7.../... 70°C/B 6...30V - 2.80 VA 2x6...15V - 2x1.40 VA x*   ukf 23.0 34.4 140
 EI30-Y10/4.../... 40°C/B 6...28V - 3.60 VA 2x6...14V - 2x1.80 VA     ukf 23.0 34.4 140
 EI30-Y10F/7.../... 70°C/B 6...32V - 4.00 VA 2x6...16V - 2x1.80 VA     bkf 23.0 34.4 140
 EI30-Y10F/4.../... 40°C/B 6...30V - 4.80 VA 2x6...15V - 2x2.20 VA     bkf 23.0 34.4 140

  • Approved to EN 61558, UL 506 UL 1585 CI.2 and C1.3, C22.2
  • Vacuum cast
  • Two chamber coil
  • Safety class II
  • Protective system IP 00
  • Absolutely short circuit proof (*ukf),
    or conditionally short circuit proof (*bkf) through temperature fuse


Note: If using conditionally short circuit proof transformer type (*bkf), no strip conductors may be guided between the primary connecting pins on the component side, because in this area there is an unprotected live soldering terminal


Variants available upon request


Top of page