Encapsulated Toroids 230V, 2xSec, 15-500VA, UL
High quality encapsulated toroidal transformers with a single 230V a.c., 50/60Hz primary winding. Twin secondary windings may be connected in series or parallel or used independently. Designed for easy mounting with centre hole fixing.
- Fully encapsulated
- Small size and low weight compared with traditional stacked lamination types
- Extremely low level of radiated magnetic field
- Very low induced noise (hum)
- Very low iron loss
- Double insulated primary leads
- 100% electrical and flash tested
- High quality manufacturing and testing in accordance to:
EN61558, EN60742, EN60950, EN60065, VDE0551, VDE0550 and BS415
- Tested and Approved by KEMA to EN61558.
- UL Recognised to UL506
|
|
|
Rated VA |
Part Number
(xxx=Sec. voltage) |
Regulation %
Typical |
Temperature Rise
[K] |
Dimensions*
Diameter [mm] |
Height
[mm] |
Fixing Hole |
Weight
[Kg] |
15 |
0015P1-2-xxxK |
16 |
26 |
63 |
35 |
M5 |
0.30 |
30 |
0030P1-2-xxxK |
18 |
40 |
82 |
39 |
M5 |
0.45 |
50 |
0050P1-2-xxxK |
14 |
42 |
87 |
42 |
M5 |
0.65 |
80 |
0080P1-2-xxxK |
14 |
53 |
104 |
44 |
M6 |
0.90 |
120 |
0120P1-2-xxxK |
10 |
52 |
104 |
52 |
M6 |
1.20 |
160 |
0160P1-2-xxxK |
9 |
55 |
115 |
53 |
M6 |
1.50 |
225 |
0225P1-2-xxxK |
8 |
60 |
126 |
52 |
M6 |
2.00 |
300 |
0300P1-2-xxxK |
8 |
60 |
126 |
65 |
M6 |
2.30 |
500 |
0500P1-2-xxxK |
6 |
68 |
148 |
65 |
M8 |
3.50 |
- Leads: PVC insulated 150mm long.
- Secondary voltage tolerance: <1% at nominal input and full load
- Maximum ambient operating temperature 40°C
- UL recognised for Insulation Class A (105°C)
- Meets all requirements of class E (120°C)
Important Installation Note
Fixing screws are not provided. Under no circumstances should both ends of the fixing bolt contact a metal chassis or frame as this would create a "shorted turn" causing irreparable damage.
Top of page
|
|