Mini toroidal transformer, 2x115V, 1.6-50VA, UL
High quality miniature open style toroidal transformers with two 115V, 50/60Hz primary windings suitable for connection in series to 230V supply, or parallel to 115V supply. Twin secondary windings may be connected in series, parallel or used independently. |
|
|
|
|
Standard Power
Max Power
Connections |
|
Click here for 0-115-230V versions (60000 series)
- Very Small size and low weight compared with traditional stacked lamination types.
- Extremely low level of radiated magnetic field
- Very low induced noise (hum)
- Very low iron loss.
- Double insulated primary leads.
- 100% electrical and flash tested
- High quality manufacturing and testing in accordance to EN61558, EN60742, EN60950, EN60065, VDE0551, VDE0550 and BS415
- Tested and Approved by KEMA to EN61558.
- UL Recognised to UL506, under family approval file E215495
Series 62000 - Two 115V primary windings for series or parallel connections.
Power VA |
Part No. |
Sec-Full Load Voltage |
Sec Current mA |
Open Circuit Voltage |
1.6 |
62000
62001
62002
62003
62004
62005 |
2x7
2x9
2x12
2x15
2x18
2x22 |
114
89
67
53
44
36 |
2x8.94
2x11.63
2x15.43
2x19.30
2x23.41
2x28.19 |
3.2 |
62010
62011
62012
62013
62014
62015 |
2x7
2x9
2x12
2x15
2x18
2x22 |
229
178
133
107
89
73 |
2x10.2
2x13.0
2x17.3
2x21.4
2x25.7
2x30.5 |
5.0 |
62020
62021
62022
62023
62024
62025 |
2x7
2x9
2x12
2x15
2x18
2x22 |
357
278
208
167
139
114 |
2x9.7
2x12.4
2x17.0
2x21.3
2x25.5
2x30.5 |
7.0 |
62030
62031
62032
62033
62034
62035 |
2x7
2x9
2x12
2x15
2x18
2x22 |
500
389
292
233
194
159 |
2x9.5
2x12.2
2x16.2
2x20.3
2x24.3
2x29.7 |
10.0 |
62040
62041
62042
62043
62044
62015 |
2x7
2x9
2x12
2x15
2x18
2x22 |
714
556
417
333
278
227 |
2x8.3
2x10.8
2x14.4
2x18.0
2x21.7
2x26.3 |
15.0 |
62050
62051
62052
62053
62054
62055 |
2x7
2x9
2x12
2x15
2x18
2x22 |
1,071
833
625
500
417
341 |
2x8.9
2x10.8
2x14.4
2x18.0
2x22.2
2x27.2 |
25.0 |
62060
62061
62062
62063
62064
62065 |
2x7
2x9
2x12
2x15
2x18
2x22 |
1,785
1,377
1,041
832
694
568 |
2x8.3
2x10.7
2x14.2
2x17.8
2x21.4
2x26.2 |
35.0 |
62070
62071
62072
62073
62074
62075 |
2x7
2x9
2x12
2x15
2x18
2x22 |
2,500
1,944
1,458
1,666
972
795 |
2x8.24
2x10.6
2x14.0
2x17.6
2x20.9
2x25.7 |
50.0 |
62080
62081
62082
62083
62084
62085 |
2x7
2x9
2x12
2x15
2x18
2x22 |
3,571
2,777
2,083
1,666
1,388
1,136 |
2x8.1
2x10.4
2x13.8
2x17.3
2x20.7
2x25.4 |
Top of page
Mini Toroidal Transformer, Maximum Power (*) (Measurements @ 20°C)
Power VA |
(*)VA |
(*)Delta Volts(%) |
(*)Delta Temp. °C |
(*)Eff. (%) |
(*)Rec. fuse (mA) |
1.6
3.2
5.0 |
2.0
3.7
5.5 |
60
80
80 |
30
40
40 |
60
50
50 |
32
50
63 |
7.0
10.0
15.0 |
7.5
12.0
16.0 |
70
60
60 |
40
45
40 |
60
60
65 |
80
100
125 |
25.0
35.0
50.0 |
-
-
- |
-
-
- |
-
-
- |
-
-
- |
-
-
- |
Top of page
Mini Toroidal Transformer, Nominal Power, (Measurements @ 20°C)
Power VA |
Dimensions
ODxIDxHT (mm) |
Weight (grams) |
Regulation
Delta Volts (%) |
Delta Temp. °C |
Eff. (%) |
No-load (mA) |
230V fuse (mA) |
1.6
3.2
5.0 |
37.5x7.0x17.0
42.0x7.0x17.5
47.0x6.0x18.0 |
71
89
115 |
29
41
45 |
10
20
29 |
77
70
70 |
1.0
1.5
2.0 |
32
32
50 |
7.0
10.0
15.0 |
47.0x6.8x21.5
53.5x6.8x23.5
57.5x7.0x24.0 |
145
216
262 |
34
20
23 |
25
24
27 |
74
82
81 |
3.0
3.0
4.0 |
63
80
100 |
25.0
35.0
50.0 |
58.0x13.8x34.5
72.0x17.0x33.5
78.0x22.5x35.0 |
388
453
670 |
19
17.7
15.5 |
28
31
30 |
84
85
86 |
5.0
7.0
8.0 |
160
200
315 |
Top of page
- Primary-Secondary test voltage 4.0 KV.
- Primaries and secondaries for parallel or series hook-up.
- Ambient operating temperature +60°C
- Maximum Insulation Class A (105°C)
- Meets all requirements of Class E(125°C).
Important Installation Note
Each transformer is supplied with a resin centre, with through-hole for single bolt fixing.
Under no circumstances should both ends of the fixing bolt contact a metal chassis or frame as this would create a "shorted turn" causing irreparable damage.
Top of page
|
|