NORDTEK DANMARK - Toroid Transformer 230V, 2xSec, 120VA - servicekontoret.dk |
||||||||||||||||||||||||||||||||||||||||
Toroid Transformer 230V, 2xSec, 120VAHigh quality open style 120VA toroidal transformers with a single 230 V a.c. 50/60Hz primary winding. Twin secondary windings may be connected in series, parallel or used independently.
Primary WindingInput Voltage Range: 230V ± 10% (207V - 253V) @ 50/60HzDC Resistance @ 25°C = Approx 16 Ohms Magnetising Current @ 230V = Approx 8.5mA Magnetising Current @ 253V = Approx 45.0mA LossesIron Losses 0.73 Watts approxCopper Losses 15.2 Watts approx Temperature ClassWinding Wire (Primary & Secondary) - Class H (180°C)Insulation between input and output - Class B (130°C) Connection lead insulation - Class A (105°C) StandardsApproved to UL506: File E215495Approved to EN61558: KEMA Certificate 2001469 Conforms to EN60065, VDE0550, BS415. Physical DataApproximate Dimensions:Diameter 93mm - (Measured away from lead-out bulge; Allow extra 4mm at leads.) Height 46mm Approximate Weight: 1.20 Kg TerminationsPrimary:Solid copper conductors (extension of winding wire), insulated over their entire length with PVC tubing. Double-insulated over entire length with Class A PVC tubing. 150mm Long, 10mm tinned ends. Secondary: Solid copper conductors (extension of winding wire), insulated over their entire length with PVC tubing. 150mm Long, 10mm tinned ends. Mounting HardwareEach transformer is supplied with a mounting kit, comprising: 2 pieces of Neoprene Insulating discs, 1 piece of Dished Steel WasherSee other power variants here: 230V, 2xSec, 15-1000VA Top of page |
||||||||||||||||||||||||||||||||||||||||
|